I am wanting to run water line about 250 feet to my garden. Thinking
about using a ditch witch. Are these hard to use?


Will there be very little pressure going that far? I plan on using
sprinklers to cover my 50 x 50 goot garden.


Also, the garden is not perfectly straight inline with the area of the
house the waterline would need to come out of. Is this a problem.


Also in between the two are my fiel lines? How do I get around that?


dps 04-02-2005 04:51 PM

Installing a permanent water line sure beats handling (and re-handling)
250' of hose.

Last time I used a ditch witch it made a really nice trench 4" wide and
18" deep. (except where it encountered a pile of rocks). It made an
excellent water line trench. The ditch witch itself was a real bear to
operate. First of all, it weighs around 800 lb. Don't plan on putting it
into your car's trunk. It had wheels which could be driven together or
separately. Steering was basically nonexistent. You had to kind of lean
on the handlebars sideways to keep the thing going in the direction you
wanted. To make a sharp turn, it was easier to lift the digging bar,
reposition the witch and start a new trench. If you can't lift really
heavy things, get a friend who can to help you run the ditch witch.

Use 1" or larger polyethylene tubing (the black stuff). It will hold up
to occasional freezes. It resists UV where it sticks out of the ground.
You can put a hose connection at both ends and just let the end stick
out of the ground. If you want to be fancy, put a pressure treated 2x4
at the end and use some of the metal pipe clamps (you need some of them
anyway to connect plumbing connectors to the PE tubing) to hold the PE
tubing on. You can put a faucet at the garden end, although I recommend
using a T and putting two faucets there. You can fill a bucket while a
hose is watering something. Using 1" tubing will reduce the line
pressure drop. Home Despot carries all that stuff.

At the house end, I just use a washing machine hose (about 4' with two
female couplers) to connect the PE tubing to the hose cock.

At the low point in the line, install a valve box and put a drain valve
there so you can let the water out for the winter. Alternatively you can
buy an air compressor and blow out the line in the fall. The valve is
cheaper. If there are any ball valves in the line, make sure they're
open over the winter.

If you know where your fuel lines are, I would strongly advise using a
shovel to dig by hand in that region. If you don't know where they are,
either go as far around as you can to avoid the area or get professional
help on the installation.



wrote:
Feb 4, 6:40 am show options

Newsgroups: alt.home.repair
From: - Find messages by this author
Date: 4 Feb 2005 06:40:59 -0800
Local: Fri, Feb 4 2005 6:40 am
Subject: Running water line.
Reply | Reply to Author | Forward | Print | Individual Message | Show
original | Remove | Report Abuse

I am wanting to run water line about 250 feet to my garden. Thinking
about using a ditch witch. Are these hard to use?


Will there be very little pressure going that far? I plan on using
sprinklers to cover my 50 x 50 goot garden.


Also, the garden is not perfectly straight inline with the area of the
house the waterline would need to come out of. Is this a problem.


Also in between the two are my fiel lines? How do I get around that?


Bob 04-02-2005 04:58 PM


"dps" wrote in message
news:4203a825$0$578$b45e6eb0@senator-
Use 1" or larger polyethylene tubing (the black stuff). It will hold up
to occasional freezes.


I used 1" for my whole sprinkler system. For a 250 foot run, I'd certainly
want something bigger. You'd get better pressure.

Bob



dps 04-02-2005 05:15 PM

I used 1.25" stuff for a 700' run. The pressure drop does not appear to
be more than about 10psi at 5gpm. Since the pressure starts at 40-50 psi
I think I still have enough to work with. The 1.25" polyethylene tubing
was a bit more expensive than the 1" stuff, but was still affordable.
1.5" is probably available at HD also. Larger than that gets pricey and
you'll have to go somewhere else to find it.


Bob wrote:
...I used 1" for my whole sprinkler system. For a 250 foot run, I'd certainly
want something bigger. You'd get better pressure.

Bob



Steve Wolfe 04-02-2005 05:43 PM

I used 1" for my whole sprinkler system. For a 250 foot run, I'd certainly
want something bigger. You'd get better pressure.


If the water pressure coming from the main is significantly higher than
what the sprinkling system will use, then run high-pressure along the long
run, and put a regulator at the other end of it. In my area, the water
pressure fluctuates between 95 and 105 PSI, so it wouldn't be a problem for
me - but I realize that not everyone else is so lucky. : )

Some people don't even use a regulator on their sprinkler systems, they
just hook 12 or more heads on a single circuit. With all of that flow and
the restriction of 3/4" pipes, it ends up dropping the pressure enough that
heads don't blow up... but the water hammer is unbelievable!

steve



Bob 04-02-2005 05:47 PM

5 gpm isn't very much for a sprinkler system. If he's just running one
sprinkler at a time, 1" might do it.

Bob

"dps" wrote in message
...
I used 1.25" stuff for a 700' run. The pressure drop does not appear to
be more than about 10psi at 5gpm. Since the pressure starts at 40-50 psi
I think I still have enough to work with. The 1.25" polyethylene tubing
was a bit more expensive than the 1" stuff, but was still affordable.
1.5" is probably available at HD also. Larger than that gets pricey and
you'll have to go somewhere else to find it.


Bob wrote:
...I used 1" for my whole sprinkler system. For a 250 foot run, I'd

certainly
want something bigger. You'd get better pressure.

Bob





John Bachman 04-02-2005 08:53 PM

On 4 Feb 2005 06:46:28 -0800, wrote:

Feb 4, 6:40 am show options

Newsgroups: alt.home.repair
From: - Find messages by this author
Date: 4 Feb 2005 06:40:59 -0800
Local: Fri, Feb 4 2005 6:40 am
Subject: Running water line.
Reply | Reply to Author | Forward | Print | Individual Message | Show
original | Remove | Report Abuse

I am wanting to run water line about 250 feet to my garden. Thinking
about using a ditch witch. Are these hard to use?


Will there be very little pressure going that far? I plan on using
sprinklers to cover my 50 x 50 goot garden.


Also, the garden is not perfectly straight inline with the area of the
house the waterline would need to come out of. Is this a problem.


Also in between the two are my fiel lines? How do I get around that?



The ditch witch will do a good job if there are no significant rocks
but it takes a healthy fellow to operate it.

I ran a 1" line to my garden, total run about 300 feet and have plenty
of pressure to run several sprinklers at a time.

If you want a guarantee then you will have to get the specs on the
sprinkler heads and know how many you will be running at a time. That
will give the flow and pressure requirements at the sprinklers. Then
calculate the pressure drop on your line and deduct that from the head
pressure at the inlet.

If I did my system over I would install a couple of inline shutoffs
and drains for when I poke a hole in the line from time to time.

If you are in a frost area you will want to drain the system. I blow
mine out with the compressor.

John



dps 04-02-2005 09:25 PM

5 gpm is a lot for a home water system. The pipes in the house are
generally 1/2", although 3/4" pipe is sometimes found. Take a gallon jug
and see how much time it takes to fill it from your hose cock. I can get
around 5 gpm through mine (12 seconds/gallon). My kitchen sink will
produce around 2 gpm and the bathtub will do about 4.

Take a garden sprinkler and put it in a 5 gallon bucket. My guess is
that it would take significantly longer than a minute to fill the
bucket. This would be a useful exercise to do anyway, since you need to
know the rate if you want to control the amount of water your garden
gets. A 50 x 50 garden (2500 sq. ft.) needs about 1550 gallons (US) to
approximate 1" of rain. (1" over 2500 sqft = 208 cubic ft, about 7.5
gallons/cubic ft [Handbook of Chemistry and Physics, 37th ed.]). This is
one reason why drip irrigation is so popular with large growers. The
water can be applied to the crop, and not to the weeds between the crop.
You can possibly reduce your water useage by a factor of 10.

A 50 x 50 garden could be covered by one sprinkler moved around on a
regular basis. I've done it on a 75 x 100 garden, but it takes several days.




Bob wrote:
5 gpm isn't very much for a sprinkler system. If he's just running one
sprinkler at a time, 1" might do it.

Bob


dps 04-02-2005 09:28 PM

The easiest way to reduce the water pressure is to just not open the
valve all the way. This isn't a precision application: a factor of two
in application rate is within reason.



Steve Wolfe wrote:
...If the water pressure coming from the main is significantly higher than
what the sprinkling system will use, then run high-pressure along the long
run, and put a regulator at the other end of it. In my area, the water
pressure fluctuates between 95 and 105 PSI, so it wouldn't be a problem for
me - but I realize that not everyone else is so lucky. : )

Some people don't even use a regulator on their sprinkler systems, they
just hook 12 or more heads on a single circuit. With all of that flow and
the restriction of 3/4" pipes, it ends up dropping the pressure enough that
heads don't blow up... but the water hammer is unbelievable!

steve



dps 04-02-2005 09:35 PM

John Bachman wrote:
... The ditch witch will do a good job if there are no significant rocks
but it takes a healthy fellow to operate it...



When I first used a ditch witch it did a great job, making a nice narrow
4" wide trench until I came to a foundation for a stone wall that had
become buried over the years. Man, did that thing jump around. It
actually managed to pull out the rocks (they stalled the ditch witch
several times), some of which had dimensions in the 8-12" range. The
resulting hole was about 2' wide at that point.

I also found a buried barn foundation. Those rocks were in the 3' range.
The ditch witch didn't move them much, but they certainly moved the
ditch witch around.

It takes at least two healthy fellows to operate it safely.

Travis 05-02-2005 12:01 AM

dps wrote:
The easiest way to reduce the water pressure is to just not open the
valve all the way. This isn't a precision application: a factor of
two in application rate is within reason.


That will only reduce the volume.

--

Travis in Shoreline (just North of Seattle) Washington
USDA Zone 8b
Sunset Zone 5



John Bachman 05-02-2005 12:52 AM

On Fri, 04 Feb 2005 16:35:14 -0500, dps
wrote:

John Bachman wrote:
... The ditch witch will do a good job if there are no significant rocks
but it takes a healthy fellow to operate it...



When I first used a ditch witch it did a great job, making a nice narrow
4" wide trench until I came to a foundation for a stone wall that had
become buried over the years. Man, did that thing jump around. It
actually managed to pull out the rocks (they stalled the ditch witch
several times), some of which had dimensions in the 8-12" range. The
resulting hole was about 2' wide at that point.

I also found a buried barn foundation. Those rocks were in the 3' range.
The ditch witch didn't move them much, but they certainly moved the
ditch witch around.

It takes at least two healthy fellows to operate it safely.


It is a soil moving machine, not a rock extractor.

John



Bob 08-02-2005 02:58 AM


"dps" wrote in message
...
5 gpm is a lot for a home water system.


My largest sprinkler "zones" run about 20 gpm.

Bob



Bob 08-02-2005 03:00 AM


"Travis" wrote in message
news:e1UMd.7471$uc.2799@trnddc09...
dps wrote:
The easiest way to reduce the water pressure is to just not open the
valve all the way. This isn't a precision application: a factor of
two in application rate is within reason.


That will only reduce the volume.


Sorry. It reduces both the pressure and the volume at the sprinkler heads.

Bob



dps 08-02-2005 12:51 PM

Where I live, everyone is on private wells. No public water. It's
possible that a public water system could deliver more pressure/volume
than an individual well (after all, they have to be able to supply fire
hydrants).

Most people will still be limited by the size of the pipe within the
home leading to the hose cock. 1/2" pipe is most common in older homes
with 3/4 used for some of the main runs. I wouldn't know about newer homes.



Bob wrote:
"dps" wrote in message
...

5 gpm is a lot for a home water system.



My largest sprinkler "zones" run about 20 gpm.

Bob