martinandfiona 27-04-2010 07:47 PM

Pump Failure
 
Hi

After three or four power failures in quick succession my pond pump has stopped working, there seems to be no power to the motor. I have checked a looked at the obvious wiring and fuse faults all ok. So im just wondring if the pump has had it or can it possibly be repaired.

The pump is a Hozelock Titan 2000

Many thanks for reading and possibly giving me advice.

Mad as a Box of Frogs[_4_] 27-04-2010 10:20 PM

Pump Failure
 
In article ,
martinandfiona wrote:

Hi

After three or four power failures in quick succession my pond pump has
stopped working, there seems to be no power to the motor. I have checked
a looked at the obvious wiring and fuse faults all ok. So im just
wondring if the pump has had it or can it possibly be repaired.

The pump is a Hozelock Titan 2000

Many thanks for reading and possibly giving me advice.




--
martinandfiona


The forum has moved to rec.ponds.moderated on Google groups.

http://groups.google.com/group/rec.p...derated/topics

Also recommend Googling the manufacturer's name and calling them for a
ruling. Also check your local craigslist buy and sell ads for a slightly
used pump replacement. There are some excellent deals there.

hth


--
"Ward, weren't you a little hard on The Beaver last night?" --June Cleaver


berrymilan 26-07-2010 10:19 AM

It looks like there is some trouble in your pump. You should try to repair your pump. I hope this trick will definitely work for you. Good Luck....

arlenpalmer 28-04-2011 07:09 PM

A pump is composed of two parts - part of dry and wet sections. Dry Day is the motor located here. The drive and move the wet part. Wet Branch impeller water is responsible for mobile. The main symptoms and hot tub pump failure-related causes are the following.
* a harsh noise or complaints - usually from the bearings getting worn out.
* Motor does not run the component failure - which may lead to soft or loud hum.
* freeze wells and broken bearings also prevent the running motor.
* start capacitor may deteriorate, to prevent start the motor.
* impeller may be jammed, the motor may not start, as a result.
* Seal leaks around the pump - which resulted in the sump pump under the water.