  #1   Report Post  
Old 26-03-2005, 12:16 AM
Reel McKoi
 
Posts: n/a
Default Pump flipping breaker... :-(

My 1200 gph pump is flipping the breaker. AAARRGGGHHHH! It's a thermally
protected Beckett. How is water getting to the "juice?" I don't suppose
they can be fixed - anyone?

I had to scramble to hook up a 500 gph just to keep the water moving. :-(
--
McKoi.... the frugal ponder...
~~~ }((((o ~~~ }{{{{o ~~~ }(((((o

  #2   Report Post  
Old 26-03-2005, 03:08 AM
rtk
 
Posts: n/a
Default

Reel McKoi wrote:
My 1200 gph pump is flipping the breaker. AAARRGGGHHHH! It's a thermally
protected Beckett. How is water getting to the "juice?" I don't suppose
they can be fixed - anyone?

I had to scramble to hook up a 500 gph just to keep the water moving. :-(


I'm having the exact same problem. Now I have to buy smaller pumps.
Big pain in the butt. I have a 500 and a 2000 gallon ponds. Any
recommendations for size pumps? Each has to travel more than 10 feet of
hose, but very little elevation to their falls.

Ruth Kazez
  #3   Report Post  
Old 26-03-2005, 03:16 AM
Gale Pearce
 
Posts: n/a
Default


"Reel McKoi" wrote in message
...
My 1200 gph pump is flipping the breaker. AAARRGGGHHHH! It's a thermally
protected Beckett. How is water getting to the "juice?" I don't suppose
they can be fixed - anyone?


Probably past a worn seal - how old is it? Do you dry store your pump for
the winter? - I always leave my pump in the pond over winter so the seals
don't dry out and pull it in the spring to clean it up for the summer when I
start it. I also ruined my first pump in a year by using the cord to "help"
get it out of the pond even though I was warned about not pulling on the
cord in any way - Beckett's are good pumps and no, I have never heard of
anyone fixing a pump with a problem like yours. Maybe your GFIC breaker is
getting weak, but still good enough to power a smaller 500 gph pump?
Gale :~)


  #4   Report Post  
Old 26-03-2005, 05:46 AM
Reel McKoi
 
Posts: n/a
Default


"rtk" wrote in message
...
Reel McKoi wrote:
My 1200 gph pump is flipping the breaker. AAARRGGGHHHH! It's a

thermally
protected Beckett. How is water getting to the "juice?" I don't

suppose
they can be fixed - anyone?

I had to scramble to hook up a 500 gph just to keep the water moving.

:-(
=======================
I'm having the exact same problem. Now I have to buy smaller pumps.


$ I plan to replace mine with one the same size. It runs the filter and the
settling tank/VF. This pump is only about 5 years old and runs about 7
months a year. What a bummer!

Big pain in the butt. I have a 500 and a 2000 gallon ponds. Any
recommendations for size pumps? Each has to travel more than 10 feet of
hose, but very little elevation to their falls.


Ruth Kazez

--
McKoi.... the frugal ponder...
~~~ }((((o ~~~ }{{{{o ~~~ }(((((o

  #5   Report Post  
Old 26-03-2005, 05:52 AM
Reel McKoi
 
Posts: n/a
Default


"Gale Pearce" wrote in message
...

"Reel McKoi" wrote in message
...
My 1200 gph pump is flipping the breaker. AAARRGGGHHHH! It's a

thermally
protected Beckett. How is water getting to the "juice?" I don't

suppose
they can be fixed - anyone?


Probably past a worn seal - how old is it?


# It's about 5 years old.

Do you dry store your pump for
the winter? -


# Yes. I bring them in, clean them and store them in the sunroom.

I always leave my pump in the pond over winter so the seals
don't dry out and pull it in the spring to clean it up for the summer when

I
start it. I also ruined my first pump in a year by using the cord to

"help"
get it out of the pond even though I was warned about not pulling on the
cord in any way -


# My husband thinks the seal is worn and that's how the water is meeting
the electricity. I haven't pulled on the cord to lift it. I lift it from
the pond by the outflow hose.

Beckett's are good pumps and no, I have never heard of
anyone fixing a pump with a problem like yours.


# That's what I figured. :*(

Maybe your GFIC breaker is
getting weak, but still good enough to power a smaller 500 gph pump?
Gale :~)


# All the other pumps (4 smaller ones) are running fine. I don't think it's
the breaker. Oh well, it's off to Home Depot tomorrow in hopes they still
carry them.
--
McKoi.... the frugal ponder...
~~~ }((((o ~~~ }{{{{o ~~~ }(((((o






  #6   Report Post  
Old 26-03-2005, 04:04 PM
PlainBill
 
Posts: n/a
Default

On Fri, 25 Mar 2005 17:16:20 -0600, "Reel McKoi" wrote:

My 1200 gph pump is flipping the breaker. AAARRGGGHHHH! It's a thermally
protected Beckett. How is water getting to the "juice?" I don't suppose
they can be fixed - anyone?

I had to scramble to hook up a 500 gph just to keep the water moving. :-(


I've had this happen with two Beckett's. In each case, it wasn't an
overload, but current leakage that tripped the GFCI. If you
disassemble it, you can see the problem - the o-ring that seals the
motor to the housing. I'd suggest giving it a week or more to dry
out, then coating the o-ring with either silicon grease (available
from a pool store) or rtv cement. Since it's going into a pond, give
the rtv plenty of time to cure and the byproducts to dissipate.

PlainBill
  #7   Report Post  
Old 26-03-2005, 06:36 PM
Mike Patterson
 
Posts: n/a
Default

On Fri, 25 Mar 2005 17:16:20 -0600, "Reel McKoi" wrote:

My 1200 gph pump is flipping the breaker. AAARRGGGHHHH! It's a thermally
protected Beckett. How is water getting to the "juice?" I don't suppose
they can be fixed - anyone?

I had to scramble to hook up a 500 gph just to keep the water moving. :-(


First make sure the pump alone is the problem -

If there is anything else on that circuit, unplug it, then try the
pump again - still trippping the breaker?

If you have a clue about electricity, try swapping that breaker with
another breaker of the same size in your panel.

Try plugging the pump into a different circuit to see if it still
trips the breaker.

Is there any place that water or bugs, ants, plants, etc. might be
getting to the wiring? Maybe an outside receptacle box, light fixture,
etc etc etc?

Examine the wire on the pump, every inch of it, paying special
attention to the plug and where it enters the pump, If it normally
runs along the ground at any point, someone (or something like a deer)
might have stepped on it and caused a puncture or pulled it apart
enough to cause a short between internal wires. The outer sheath may
not even be broken but the wires inside still can be - look for kinks
in the wire.


Just some thoughts.
Mike


Mike Patterson
Please remove the spamtrap to email me.
"I always wanted to be somebody...I should have been more specific..." - Lily Tomlin

--
Posted via NewsDemon.com - Premium Uncensored Newsgroup Service
-------http://www.NewsDemon.com------
Unlimited Access, Anonymous Accounts, Uncensored Broadband Access
  #8   Report Post  
Old 26-03-2005, 11:21 PM
Reel McKoi
 
Posts: n/a
Default


"PlainBill" wrote in message
news
On Fri, 25 Mar 2005 17:16:20 -0600, "Reel McKoi" wrote:

My 1200 gph pump is flipping the breaker. AAARRGGGHHHH! It's a

thermally
protected Beckett. How is water getting to the "juice?" I don't suppose
they can be fixed - anyone?

I had to scramble to hook up a 500 gph just to keep the water moving.

:-(

I've had this happen with two Beckett's. In each case, it wasn't an
overload, but current leakage that tripped the GFCI. If you
disassemble it, you can see the problem - the o-ring that seals the
motor to the housing.


## YEP!!! When we opened the pump about 1/4 cup of water ran out. We
allowed it to dry out all day and sealed it with GREASE. Hubby tightened
them nicely this time. Also, the screws were not real tight when I
unscrewed them - probably causing a poor seal. :-( Home Depot no longer
carries these pumps nor does Foster&Smith. We don't know if the is grease
will work so ordered another pump just in case, a Pondmaster Mag Drive @
1800 gph. Price w/shipping & handling came to $140.98.

I'd suggest giving it a week or more to dry
out,


## He wouldn't wait. We left it in the hot sun to dry and it was dry by the
time we got back from town. I would have waited a few days.

then coating the o-ring with either silicon grease (available
from a pool store) or rtv cement.


## No pool stores here. No one had heard of rtv cement at Lowe's or Home
Depot. All we could find was silicon "oil" so my husband used Dielectric
grease.

Since it's going into a pond, give
the rtv plenty of time to cure and the byproducts to dissipate.


## What is the full name of rtv cement? What is it usually used for?

--
McKoi.... the frugal ponder...
~~~ }((((o ~~~ }{{{{o ~~~ }(((((o

  #9   Report Post  
Old 26-03-2005, 11:29 PM
Reel McKoi
 
Posts: n/a
Default


"Mike Patterson" wrote in message
...
On Fri, 25 Mar 2005 17:16:20 -0600, "Reel McKoi" wrote:

My 1200 gph pump is flipping the breaker. AAARRGGGHHHH! It's a

thermally
protected Beckett. How is water getting to the "juice?" I don't suppose
they can be fixed - anyone?

I had to scramble to hook up a 500 gph just to keep the water moving.

:-(

First make sure the pump alone is the problem -


## Thanks Mike, we believe it was. All the others were checked and didn't
flip the breaker. See my post above. Water had leaked past the heavy
rubber seal seal. The seal itself looked in good shape.

If there is anything else on that circuit, unplug it, then try the
pump again - still trippping the breaker?


## It sure was.....

If you have a clue about electricity, try swapping that breaker with
another breaker of the same size in your panel.
Try plugging the pump into a different circuit to see if it still
trips the breaker.

Is there any place that water or bugs, ants, plants, etc. might be
getting to the wiring? Maybe an outside receptacle box, light fixture,
etc etc etc?


## We checked all those things before opening the pump - to find water
INSIDE, past the seal. :-(

Examine the wire on the pump, every inch of it, paying special
attention to the plug and where it enters the pump, If it normally
runs along the ground at any point, someone (or something like a deer)
might have stepped on it and caused a puncture or pulled it apart
enough to cause a short between internal wires. The outer sheath may
not even be broken but the wires inside still can be - look for kinks
in the wire.


## That's something we need to do. I need to clean the wire of mud and
slime and check it real good. We're sure it was the water that passed the
seal causing the problem. I hope the grease, resetting the seal and
tightening the screws worked. The water is already turning a greenish
brown - and Foster&Smith says it'll take a week to get the new pump to us.
We're going to plug the Versa in tomorrow and see if the seal is ok now. In
that case we'll keep it as a backup pump.
--
McKoi.... the frugal ponder...
~~~ }((((o ~~~ }{{{{o ~~~ }(((((o

  #10   Report Post  
Old 27-03-2005, 09:45 AM
Sean Dinh
 
Posts: n/a
Default

Silicone grease is available at Home Depot, in the plumping
section. I've used it on O-ring when replacing the O-ring in
faucet and bath water valves.

I've never heard of rtv cement. I've used rtv silicone to
make gaskets. They're in auto stores.

Use silicone grease to seal O-ring on turning shaft. Use rtv
silicone to seal stationary parts.


  #11   Report Post  
Old 27-03-2005, 06:30 PM
Reel McKoi
 
Posts: n/a
Default


"Sean Dinh" wrote in message
...
Silicone grease is available at Home Depot, in the plumping
section. I've used it on O-ring when replacing the O-ring in
faucet and bath water valves.

I've never heard of rtv cement. I've used rtv silicone to
make gaskets. They're in auto stores.

Use silicone grease to seal O-ring on turning shaft. Use rtv
silicone to seal stationary parts.

=========================
Thanks Sean. I'll let you guys know if the grease my husband used worked or
not. I'm going to plug it in as soon as I finish my morning coffee here.
If it didn't work - then this week we'll check out the Auto Zone in
town.....
--
McKoi.... the frugal ponder...
~~~ }((((o ~~~ }{{{{o ~~~ }(((((o

  #12   Report Post  
Old 27-03-2005, 08:24 PM
PlainBill
 
Posts: n/a
Default

On Sat, 26 Mar 2005 16:21:54 -0600, "Reel McKoi" wrote:


"PlainBill" wrote in message
news
On Fri, 25 Mar 2005 17:16:20 -0600, "Reel McKoi" wrote:

My 1200 gph pump is flipping the breaker. AAARRGGGHHHH! It's a

thermally
protected Beckett. How is water getting to the "juice?" I don't suppose
they can be fixed - anyone?

I had to scramble to hook up a 500 gph just to keep the water moving.

:-(

I've had this happen with two Beckett's. In each case, it wasn't an
overload, but current leakage that tripped the GFCI. If you
disassemble it, you can see the problem - the o-ring that seals the
motor to the housing.


## YEP!!! When we opened the pump about 1/4 cup of water ran out. We
allowed it to dry out all day and sealed it with GREASE. Hubby tightened
them nicely this time. Also, the screws were not real tight when I
unscrewed them - probably causing a poor seal. :-( Home Depot no longer
carries these pumps nor does Foster&Smith. We don't know if the is grease
will work so ordered another pump just in case, a Pondmaster Mag Drive @
1800 gph. Price w/shipping & handling came to $140.98.

I'd suggest giving it a week or more to dry
out,


## He wouldn't wait. We left it in the hot sun to dry and it was dry by the
time we got back from town. I would have waited a few days.

then coating the o-ring with either silicon grease (available
from a pool store) or rtv cement.


## No pool stores here. No one had heard of rtv cement at Lowe's or Home
Depot. All we could find was silicon "oil" so my husband used Dielectric
grease.

Since it's going into a pond, give
the rtv plenty of time to cure and the byproducts to dissipate.


## What is the full name of rtv cement? What is it usually used for?


I believe it's a Dow Corning trademark. GE also has a clear 'Tub and
Tile' caulk that is essentially the same thing. Essentially the stuff
reacts with moisture in the air to start the curing process. I'd give
it 24 hours to cure, just to let the volatiles dissipate. The
silicone grease your husband used is about the same thing, except it
never cures.

PlainBill
  #13   Report Post  
Old 28-03-2005, 12:03 AM
Reel McKoi
 
Posts: n/a
Default


"PlainBill" wrote in message
...
On Sat, 26 Mar 2005 16:21:54 -0600, "Reel McKoi" wrote:
I believe it's a Dow Corning trademark. GE also has a clear 'Tub and
Tile' caulk that is essentially the same thing. Essentially the stuff
reacts with moisture in the air to start the curing process. I'd give
it 24 hours to cure, just to let the volatiles dissipate. The
silicone grease your husband used is about the same thing, except it
never cures.

==============
If water still leaks in we'll know what to get and where to get it....
So far so good - the pump's been running for hours... :-)
--
McKoi.... the frugal ponder...
~~~ }((((o ~~~ }{{{{o ~~~ }(((((o

  #14   Report Post  
Old 29-03-2005, 07:49 PM
Derek Broughton
 
Posts: n/a
Default

Reel McKoi wrote:

## YEP!!! When we opened the pump about 1/4 cup of water ran out. We
allowed it to dry out all day and sealed it with GREASE. Hubby tightened
them nicely this time. Also, the screws were not real tight when I
unscrewed them - probably causing a poor seal. :-( Home Depot no
longer
carries these pumps nor does Foster&Smith. We don't know if the is grease
will work so ordered another pump just in case, a Pondmaster Mag Drive @
1800 gph. Price w/shipping & handling came to $140.98.

There's pros and cons there. The pondmaster should never have this problem,
as afaik the motor is epoxy encased. otoh, you can't ever give it even a
temporary fix by slapping a lot of grease in it :-) on the whole though,
I've heard much better things about the Pondmasters than about Beckets.
--
derek
  #15   Report Post  
Old 30-03-2005, 12:48 AM
~Roy~
 
Posts: n/a
Default



Becketts are pityfull pumps compared to Danner Pond
Master....Pondmasters have the top end hands down, in regards to life
expectency, non-oil filled, no seals to leak, and less power
consumption. For what the big box stores charge for a Becket or Little
Giant, you can get a great pondmaster.....plus most models are capable
of submerged or outside the water use...





On Tue, 29 Mar 2005 13:49:34 -0400, Derek Broughton
wrote:

===Reel McKoi wrote:
===
=== ## YEP!!! When we opened the pump about 1/4 cup of water ran out. We
=== allowed it to dry out all day and sealed it with GREASE. Hubby tightened
=== them nicely this time. Also, the screws were not real tight when I
=== unscrewed them - probably causing a poor seal. :-( Home Depot no
=== longer
=== carries these pumps nor does Foster&Smith. We don't know if the is grease
=== will work so ordered another pump just in case, a Pondmaster Mag Drive @
=== 1800 gph. Price w/shipping & handling came to $140.98.
===
===There's pros and cons there. The pondmaster should never have this problem,
===as afaik the motor is epoxy encased. otoh, you can't ever give it even a
===temporary fix by slapping a lot of grease in it :-) on the whole though,
===I've heard much better things about the Pondmasters than about Beckets.



==============================================
Put some color in your cheeks...garden naked!
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
A "clay breaker"? Is this possible? VX United Kingdom 13 30-01-2006 08:33 PM
Battery Charger Part --- A-0705L --- Circuit Breaker --- besides the company Who can it be order from ?? BoNanner Lawns 3 07-01-2006 06:24 PM
OT Squirrels Flipping Out - Could this be it? Shelly Roses 2 14-09-2003 08:02 PM
OT Squirrels Flipping Out - Could this be it? Shelly Gardening 2 14-09-2003 08:02 PM
OT Squirrels Flipping Out Salty Thumb Roses 24 11-09-2003 09:32 PM


All times are GMT +1. The time now is 12:50 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 GardenBanter.co.uk.
The comments are property of their posters.
 

About Us

"It's about Gardening"

 

Copyright © 2017