I am installing an automatic irrigation system for my backyard, and am
trying to figure out the problem caused by a raised planter in the back.
Anti-siphon valves require being a foot higher than the highest sprinkler
head, so I thought I'd look into in-line valves. However, they require a
back flow prevention device which, according to Toro's website, says that it
must be intsalled a foot or so higher than the highest sprinkler head. I'd
rather not have all that hardware 4 or 5 feet above my patio. What is the
recomended way to automatically water a raised planter?

Thanks, Mike


  #2   Report Post  
Old 26-08-2004, 02:54 AM
Gardñ@Gardñ.info
 
Posts: n/a
Default


"Mike Franklin" in
news:WXaXc.62235$Fg5.24953@attbi_s53:

I am installing an automatic irrigation system for my backyard, and am
trying to figure out the problem caused by a raised planter in the
back. Anti-siphon valves


AVB, consided unreliable. unlike other backflows, you need one for each
valve, and i'ts installed AFTER each valve. ( in 'one piece' AS valves,
AVBs are glued-on, downflow of the actual valve.)

require being a foot higher than the highest
sprinkler head, so I thought I'd look into in-line valves.


you can get better brands if you buy inline valves, rainbird or hunter
are decent, imo

However,
they require a back flow prevention device which, according to Toro's
website, says that it must be intsalled a foot or so higher than the
highest sprinkler head.


sounds like toro's plastic PVB? or are they rebadging brass ones?

call your water district, see if they have type requirements. double
checks don't need ot be above the outlets.

rp's are supposedly best.
http://www.irrigationtutorials.com/sprinkler08.htm



I'd rather not have all that hardware 4 or 5
feet above my patio. What is the recomended way to automatically
water a raised planter?


hide it. keep it away from fences, espec corner posts, else someone will
bash it during fence repair.

Thanks, Mike


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Automatic sprinkler question Myrl Jeffcoat Gardening 2 01-06-2006 12:50 PM
Sprinkler Valve Question [email protected] Lawns 4 10-02-2006 03:44 PM
Sprinkler Valve Question [email protected] Gardening 0 06-02-2006 04:21 PM
honda harmony valve adjustment and tuneup? Procedure/valve clearance? Chris Miller Lawns 0 29-07-2005 02:25 AM
Gang valve after needle valve? Paulio629 Freshwater Aquaria Plants 3 13-04-2004 08:05 PM


All times are GMT +1. The time now is 04:00 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 GardenBanter.co.uk.
The comments are property of their posters.
 

About Us

"It's about Gardening"

 

Copyright © 2017