I have a small 4-zone system at my house. My property is about 100 feet
deep and 50 feet wide so the sprinkler system does not really cover much
land. The system has a Wilkins Model 420 Pressure Vacuum Breaker right
where the main water line comes out of the house before it goes to the four
zone valves. There is a drain plug in the main water line outside the
house that sits right below the Wilkins breaker. This drain plug is where
the pressure tap is connected to blow out the system.

I have a Sears 5.5 HP 25 gallon compressor that is rated at 8.6 CFM @ 40
PSI and 6.4 CFM @ 90 PSI. I have 50 feet of 3/8 copper tubing in a coil at
the output of my compressor going to a water filter and a quick release
fitting. I ran 75 feet of ½" rubber air hose (after the 50-ft copper coil)
out to the drain plug below my Wilkins breaker. I filled my compressor,
turned on one zone of my sprinkler and set turned my compressor regulator
to 50 PSI of output. I heard a lot of "gurgling" at the Wilkins breaker
but my sprinkler heads did not pop up. I raised the pressure a bit to 70
PSI but the sprinkler heads still did not pop up. I had a similar problem
last year but after a while of experimenting I got the sprinkler heads to
pop at 50 PSI and the "gurgling" went away. I am not sure how I got it to
work last year but I cannot get it to work again this year.

Does anyone have any ideas what the problem might be? Is it possible that
my compressor is not flowing enough CFM? Would it help if I pulled my
compressor out of garage and put it near the sprinkler drain plug and used
a much shorter rubber airline to hook up my pressure tap?
  #2   Report Post  
Old 16-10-2006, 12:50 PM posted to alt.home.lawn.garden
external usenet poster
 
First recorded activity by GardenBanter: Jul 2006
Posts: 431
Default Problem blowing out sprinkler


Computer Prog wrote:
I have a small 4-zone system at my house. My property is about 100 feet
deep and 50 feet wide so the sprinkler system does not really cover much
land. The system has a Wilkins Model 420 Pressure Vacuum Breaker right
where the main water line comes out of the house before it goes to the four
zone valves. There is a drain plug in the main water line outside the
house that sits right below the Wilkins breaker. This drain plug is where
the pressure tap is connected to blow out the system.

I have a Sears 5.5 HP 25 gallon compressor that is rated at 8.6 CFM @ 40
PSI and 6.4 CFM @ 90 PSI. I have 50 feet of 3/8 copper tubing in a coil at
the output of my compressor going to a water filter and a quick release
fitting. I ran 75 feet of ½" rubber air hose (after the 50-ft copper coil)
out to the drain plug below my Wilkins breaker. I filled my compressor,
turned on one zone of my sprinkler and set turned my compressor regulator
to 50 PSI of output. I heard a lot of "gurgling" at the Wilkins breaker
but my sprinkler heads did not pop up. I raised the pressure a bit to 70
PSI but the sprinkler heads still did not pop up. I had a similar problem
last year but after a while of experimenting I got the sprinkler heads to
pop at 50 PSI and the "gurgling" went away. I am not sure how I got it to
work last year but I cannot get it to work again this year.

Does anyone have any ideas what the problem might be? Is it possible that
my compressor is not flowing enough CFM? Would it help if I pulled my
compressor out of garage and put it near the sprinkler drain plug and used
a much shorter rubber airline to hook up my pressure tap?



I have a similar compressor and have also seen problems like this
sometimes when blowing out my system. And I've also seen problems
where water mysteriously sprays out of the backflow preventer during
Spring start up.

I'm not an expert on what's inside the backflow preventers, but
essentially it relies on a moving plastic object being pushed by water
to close a passage. I think the problem is that air has a lot less
mass, and the widget may not move as easy with air as it would getting
hit with water. So, I think it must get stuck mid-way, with the air
continuing to go around it. This is probably less of an issue with a
compressor that can deliver more CFM. The ones we have are marginal,
though they will do the job.

I'd try the following:

1 - Go back to running water through it again. This should get the
valve operating properly again. Then you can try air again.

2 - Rap the backflow valve with a hammer to try to free it up without
air on it, then apply air and rap again if still misbehaving.

3 - Take the top cover off the backflow valve. On mine, the thing
comes apart easily with just 3 screws and you can pull out part of the
mechanism. Every time I've done that and put it back together, it's
gone back to behaving again.

  #3   Report Post  
Old 24-10-2006, 01:11 AM posted to alt.home.lawn.garden
external usenet poster
 
First recorded activity by GardenBanter: Oct 2006
Posts: 10
Default Problem blowing out sprinkler

I know it's been a few days so you may have already found out how to handle
your problem, but if you haven't, try this forum:

http://forums.gardenweb.com/forums/

There are a number of lawn/garden related topics where you should be able to
find someone who can help out.

Good luck.



"Computer Prog" wrote in message
...
I have a small 4-zone system at my house. My property is about 100 feet
deep and 50 feet wide so the sprinkler system does not really cover much
land. The system has a Wilkins Model 420 Pressure Vacuum Breaker right
where the main water line comes out of the house before it goes to the
four
zone valves. There is a drain plug in the main water line outside the
house that sits right below the Wilkins breaker. This drain plug is where
the pressure tap is connected to blow out the system.

I have a Sears 5.5 HP 25 gallon compressor that is rated at 8.6 CFM @ 40
PSI and 6.4 CFM @ 90 PSI. I have 50 feet of 3/8 copper tubing in a coil
at
the output of my compressor going to a water filter and a quick release
fitting. I ran 75 feet of ½" rubber air hose (after the 50-ft copper
coil)
out to the drain plug below my Wilkins breaker. I filled my compressor,
turned on one zone of my sprinkler and set turned my compressor regulator
to 50 PSI of output. I heard a lot of "gurgling" at the Wilkins breaker
but my sprinkler heads did not pop up. I raised the pressure a bit to 70
PSI but the sprinkler heads still did not pop up. I had a similar problem
last year but after a while of experimenting I got the sprinkler heads to
pop at 50 PSI and the "gurgling" went away. I am not sure how I got it to
work last year but I cannot get it to work again this year.

Does anyone have any ideas what the problem might be? Is it possible that
my compressor is not flowing enough CFM? Would it help if I pulled my
compressor out of garage and put it near the sprinkler drain plug and used
a much shorter rubber airline to hook up my pressure tap?



  #4   Report Post  
Old 24-10-2006, 10:28 PM posted to alt.home.lawn.garden
external usenet poster
 
First recorded activity by GardenBanter: Oct 2006
Posts: 2
Default Problem blowing out sprinkler

I moved the compressor very close to breaker and ran a short hose to
the pressure port. This allowed me to blow out my sprinklers
properly. The breaker stops "gurgling" after I give it enough airflow
to "open it", at which point the air goes to the heads and they pop up.
That point seems to be an indicated 65-70 PSI on my compressor output
gauge. Once the heads pop I can immediately reduce the air pressure
and the breaker will remain open with the heads remaining up. I
reduced it to an indicated 50 PSI after the heads popped up. The heads
will remain up even if I dial the pressure down to an indicated 25 PSI.


My compressor was not able to keep up with the airflow at 50 PSI so
the pressure dropped slowly as I blew out the lines. I had to cut the
airflow to allow the compressor to catch up a handful of times.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Gear driven sprinkler versus impact sprinkler MiamiCuse Lawns 2 11-11-2008 02:40 AM
Problem blowing out sprinklers Computer Prog Gardening 3 24-10-2006 10:30 PM
Blowing in mulch for habitat J Kolenovsky Texas 3 05-04-2003 11:10 AM
John Deere F510 Riding Mower Keeps Blowing Fuses! C R R Lawns 0 29-03-2003 02:20 PM
John Deere F510 Riding Mower Keeps Blowing Fuses! Dr. Doctor Lawns 1 28-03-2003 10:32 PM