Today I attempt to install a new Sequence 7200 pump on my 2500 gallon pond.
Will keep you posted and post some pics when done. Keep your fingers crossed that Murphy's Law is broken today..... Gary |
#2
|
|||
|
|||
Wish me luck
Wishes, and good vibes, sent your way! ~ jan )
Today I attempt to install a new Sequence 7200 pump on my 2500 gallon pond. Will keep you posted and post some pics when done. Keep your fingers crossed that Murphy's Law is broken today..... Gary ~Power to the Porg, Flow On!~ |
#3
|
|||
|
|||
Wish me luck
It works - though I would like a bit more flow. The pond is fitted with
1.5" tubing. Would upgrading to 2" make a difference? "~ jan JJsPond.us" wrote in message ... Wishes, and good vibes, sent your way! ~ jan ) Today I attempt to install a new Sequence 7200 pump on my 2500 gallon pond. Will keep you posted and post some pics when done. Keep your fingers crossed that Murphy's Law is broken today..... Gary ~Power to the Porg, Flow On!~ |
#4
|
|||
|
|||
Wish me luck
gng wrote:
It works - though I would like a bit more flow. The pond is fitted with 1.5" tubing. Would upgrading to 2" make a difference? "~ jan JJsPond.us" wrote in message ... Wishes, and good vibes, sent your way! ~ jan ) Today I attempt to install a new Sequence 7200 pump on my 2500 gallon pond. Will keep you posted and post some pics when done. Keep your fingers crossed that Murphy's Law is broken today..... Gary ~Power to the Porg, Flow On!~ larger pipe = less restriction = more flow I know this is for PVC, but it shows the relationship between different sizes Table1: Saturation Flow Rates for Schedule 40 PVC Pipe Size Approximate Saturation Flow Rate 1 inch 25 GPM 1500 GPH 1 ½ inch 60 GPM 3600 GPH 2 inch 150 GPM 9000 GPH Table 2: Maximum Recommended Flow Rates And Pump Sizes for Various Pipe Sizes Pipe Size Max Pump Size Approx. Flow Rate with Max Pump Size 1 inch 1/3 hp 15 GPM 900 GPH 1 ¼ inch ½ hp 25 GPM 2100 GPH 1 ½ inch ½ hp 45 GPM 2700 GPH 2 inch 1 hp 75 GPM 4500 GPH 2 ½ inch 1 ½ hp 110 GPM 6600 GPH 3 inch 2 hp 200 GPM 12000 GPH -- Bigger is better, and less is more /\/\ike Chagoi http://ourkoipond.com |
#5
|
|||
|
|||
Wish me luck
chagoi wrote:
larger pipe = less restriction = more flow I know this is for PVC, but it shows the relationship between different sizes Table1: Saturation Flow Rates for Schedule 40 PVC Pipe Size Approximate Saturation Flow Rate 1 inch 25 GPM 1500 GPH 1 ½ inch 60 GPM 3600 GPH 2 inch 150 GPM 9000 GPH Table 2: Maximum Recommended Flow Rates And Pump Sizes for Various Pipe Sizes Pipe Size Max Pump Size Approx. Flow Rate with Max Pump Size 1 inch 1/3 hp 15 GPM 900 GPH 1 ¼ inch ½ hp 25 GPM 2100 GPH 1 ½ inch ½ hp 45 GPM 2700 GPH 2 inch 1 hp 75 GPM 4500 GPH 2 ½ inch 1 ½ hp 110 GPM 6600 GPH 3 inch 2 hp 200 GPM 12000 GPH -- Bigger is better, and less is more /\/\ike Chagoi http://ourkoipond.com try this for tables 1 & 2 http://ourkoipond.com/psafr.htm -- /\/\ike Chagoi http://ourkoipond.com |
#6
|
|||
|
|||
Wish me luck
Thanks - it actually looks pretty good right now since the filter was
cleaned. But it looks as if I should change out the 1.5" to 2" if I want a bigger waterfall. From what I can see, it looks pretty significant. Anyone out there change out pipe size and notice a big difference? There are some areas where it must stay 1.5", such as the pipe that is cemented into the waterfall. Will this negate me changing out the rest of the pipe? Is the flow only as good as the smallest pipe size? "chagoi" wrote in message ... chagoi wrote: larger pipe = less restriction = more flow I know this is for PVC, but it shows the relationship between different sizes Table1: Saturation Flow Rates for Schedule 40 PVC Pipe Size Approximate Saturation Flow Rate 1 inch 25 GPM 1500 GPH 1 ½ inch 60 GPM 3600 GPH 2 inch 150 GPM 9000 GPH Table 2: Maximum Recommended Flow Rates And Pump Sizes for Various Pipe Sizes Pipe Size Max Pump Size Approx. Flow Rate with Max Pump Size 1 inch 1/3 hp 15 GPM 900 GPH 1 ¼ inch ½ hp 25 GPM 2100 GPH 1 ½ inch ½ hp 45 GPM 2700 GPH 2 inch 1 hp 75 GPM 4500 GPH 2 ½ inch 1 ½ hp 110 GPM 6600 GPH 3 inch 2 hp 200 GPM 12000 GPH -- Bigger is better, and less is more /\/\ike Chagoi http://ourkoipond.com try this for tables 1 & 2 http://ourkoipond.com/psafr.htm -- /\/\ike Chagoi http://ourkoipond.com |
#7
|
|||
|
|||
Wish me luck
gng wrote:
It works - though I would like a bit more flow. The pond is fitted with 1.5" tubing. Would upgrading to 2" make a difference? "~ jan JJsPond.us" wrote in message ... Wishes, and good vibes, sent your way! ~ jan ) Today I attempt to install a new Sequence 7200 pump on my 2500 gallon pond. Will keep you posted and post some pics when done. Keep your fingers crossed that Murphy's Law is broken today..... Gary ~Power to the Porg, Flow On!~ larger pipe = less restriction = more flow I know this is for PVC, but it shows the relationship between different sizes Table1: Saturation Flow Rates for Schedule 40 PVC Pipe Size Approximate Saturation Flow Rate 1 inch 25 GPM 1500 GPH 1 ½ inch 60 GPM 3600 GPH 2 inch 150 GPM 9000 GPH Table 2: Maximum Recommended Flow Rates And Pump Sizes for Various Pipe Sizes Pipe Size Max Pump Size Approx. Flow Rate with Max Pump Size 1 inch 1/3 hp 15 GPM 900 GPH 1 ¼ inch ½ hp 25 GPM 2100 GPH 1 ½ inch ½ hp 45 GPM 2700 GPH 2 inch 1 hp 75 GPM 4500 GPH 2 ½ inch 1 ½ hp 110 GPM 6600 GPH 3 inch 2 hp 200 GPM 12000 GPH -- Bigger is better, and less is more /\/\ike Chagoi http://ourkoipond.com |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Wish me luck Franklinia effort. | Gardening | |||
Wish me luck! | United Kingdom | |||
Wish me Luck! | Ponds | |||
Great luck with CA online store | Freshwater Aquaria Plants | |||
My Bad Fish Luck Continues Guys. | Ponds |